|
|
ProVU 1/4DIN Advanced Temperature / Process / Profile / Recording Control
West 1/4 DIN Advanced Process Control with Options for Ramping/Dwelling and Data Logging. Universal Input, Self Tuning
|
Price:
(Including Options)
Item Number: V4-1
V4-1-C00/1000/0001
Product Options
* denotes required field
Input
Control Type*
Profiler Option*
Power Supply*
Out #1 (Heat)*
Out #2 ( Cool/Alarm)*
Out #3 (Alarm or Retransmit)*
Option 4*
Options A*
Options B*
Options C*
Display Language*
|
1-2 Week Shipment
We will advise immediately if your order will be delayed
The ISE/West ProVU is a powerful Control with optional Programmer and Recorder Options. The ProVU includes a high contrast dual color backlit display. The display can be programmed to change colors depending on alarm status. It is packed with innovative features to control complex processes without setup complexities found in other controls. The ProVU available communications options include USB Port, Ethernet Port, RS485 Port and Configuration Port. It's simplistic operator interface is preferred by most operators.
We fully configure the control prior to shipment so that it is truly plug & play. Configurations can be easily modified if your requirements change.
|
Available Options/Configurations
Single Loop Control
Dual Loop Control (Ideal for Temperature/RH Control)
Cascade Control
Ratio Control
Valve Motor Control with Slide-wire Feedback
Gain Scheduling
Ramp/Dwell
Data Logging
Recording
USB for Memory Stick (Save full configuration for copying to other controls)
Ethernet
|
HMI Display
User operation and control
- Easy setup wizard for quick configuration (inputs, alarms, outputs, comms & real-time clock)
- Up to (2) Universal inputs for thermocouple, RTDs and linear DC process signals (mA, mV or V)
- Flexible output options, relay, ssd driver, triac & Linear DC
- Digital inputs (10 max)
- Configurable menus (via Optional BlueControl software)
- Optional USB port for local upload/download of configuration files & download logged data
- Password protected supervisor and configuration mode
- Pre-tune and self-tune function
- Master-slave configuration for multi-zone applications
Profiling function (option)
- 255 segments to allocate freely in up to 64 programs
- Ramp, dwell, hold, loop or jump to other profile
- User defined text profile names
- Delayed or real-time day/time profile start
- Up to 5 event outputs
-Datalogging Function (option)
- Historic process data for analysis or reporting
- Export data files via front USB or comms
- Log process values, setpoints or alarms (including min, max & average)
- Run-then-stop or FIFO (first in first out) buffer recording
- Logging intervals from 1s to 30m


Specifications:
| Operating Temp.:
|
0° to 55°C
|
| Storage Temp.:
|
-20° to 80°C
|
| Humidity:
|
20% to 95% non-condensing RH
|
| Supply Voltage:
|
100 to 240V 50/60Hz; optional 20 to 48VAC / 22 to 65 VDC
|
| Power Consumption:
|
20VAmax
|
| T/Cs:
|
J, K, C, R, S, T, B, L, N, D, E and Pt 20% Rh vs. Pt 40% Rh
|
| RTD:
|
3-wire; PT100; NI120 50 per lead maximum (balanced)
|
DC Linear:
(scalable 1999 to +9999)
|
Volts: 0-5V, 1-5, 0-10, or 2-10VDC
DC milliamps: 0-20mA or 4-20mA
DC millivolts: 0-50mV or 10-50mV
|
| All output types are user-selectable and customizable based on desired application; choose from the following output types:
|
| Max. # of Outputs:
|
Nine for control, alarm, 24VDC transmitter power supply or retransmit of process value or setpoint (limitations apply, see full specification for available options)
|
| Relay:
|
Optional SPDT; 240VAC 2.0A resistive. Lifetime: >500,000 operations at rated voltage/current. Reinforced safety isolation from other inputs and outputs.
|
| Dual Relay
|
Optional SPST; 240VAC 2.0A resistive. Lifetime: >200,000 operations at rated voltage/current. Reinforced safety isolation from other inputs and outputs.
|
| Quad Relay
|
Optional SPST; 240VAC 2.0A resistive. Lifetime: >500,000 operations at rated voltage/current. Reinforced safety isolation from other inputs and outputs.
|
| SSR Driver:
|
Optional drive capability: >10VDC nominal into 500 minimum
|
| DC Linear:
|
Optional 020mA , 420mA into 500 max.; 010V, 15V, 210V, 05V into 500 minimum; control outputs have 2% over/under drive applied; accuracy ±0.25% (mA into 250 load, V into 2k load); degrading linearly to ±0.5% for increasing burden to specified limits
|
| Triac:
|
Optional 0.01 to 1A AC, 20 to 280Vrms, 4763Hz (limit 2)
|
| Transmitter Power Supply:
|
Optional 24VDC (19 to 28VDC) into 910 ohm minimum
|
| All output functions are user-selectable and customisable based on the application:
|
| Heat Power
|
reverse or direct
|
| Cool Power
|
reverse or direct
|
| Process Alarm:
|
reverse or direct
|
| Alarms:
|
Up to 5 selectable as process High, process low, SP deviation, band, logical OR alarm outputs. Alarms can be configured as latching
|
| Loop Alarm:
|
reverse or direct
|
| Retransmit:
|
setpoint or process value
|
| Accuracy:
|
± 0.1% of input range ± 1 LSD (Thermocouple CJC) ; ± 0.25% of input range ± 1 LSD (Aux input)
|
| Input Sample Rate:
|
Process input 10 per second, aux input 4 per second
|
| Sensor Break Detection:
|
Detected within 2secs, control goes to user preset value
|
| Memory
|
255 segments can be freely allocated in up to 64 programs. Up to 2 profiles per program for dual loop configurations)
|
| Segment types
|
Ramp (rate or time), dwell (soak), hold, loop, join another profile, end or repeat sequence
|
| Control
|
Run, hold, abort, profile select, jump to next segment, delayed profile start, real-time clock profile start
|
| Data record options
|
PV (process variable), max and min PV between samples, actual SP (setpoint), output power, alarm & event status, power on/off
|
| Record modes
|
FIFO (circular buffer) or run-then-stop (fixed buffer)
|
| Recording interval
|
1, 2, 5, 10, 15, 30 sec or min
|
| Control
|
Manual, serial comms, digital input, synchronised with profile, PV rate of change, log on alarm
|
| Options:
|
RS232 via RJ45 cable (configuration only), RS485 - Modbus RTU master or slave, Ethernet - Modbus TCP (10 base-T or 100 base-T), Ver 1.1/2.0 USB host for memory stick
|
| PC Configuration:
|
Off-line configuration from serial port to dedicated configuration socket (comms option not required)
|
| Safety:
|
CE, UL, cUL
|
| EMC:
|
Certified EN61326
|
| Other:
|
ISO 9002 registered
|
- IEC IP66 (IP65 with USB fitted); NEMA 4X (front panel)
- IEC IP20 (behind the panel protection)
|
| Panel Cutout:
|
92mm x 92mm
|
| Width:
|
96mm
|
| Depth:
|
117mm
|
| Height:
|
96mm
|
| Weight:
|
0.65kg maximum
|
| Mounting:
|
Plug-in with panel mounting fixing strap
|
- Digital Input 1 (optional): Selects between two setpoints or auto/manual tune control, profile hold/run, profile segment release, profile abort; volt free or TTL input
- Basic Remote Setpoint Input (optional): 0-20mA, 4-20mA, 0-10V, 2-10V, 0-5V; scalable - 1999 to 9999; local or remote setpoint selected from front panel
- Full Remote Setpoint Input (Optional): 0-20mA, 4-20mA, 0-5V, 1-5V, 0-10V, 2-10V, 0-100mV; scaleable 1999 to 9999; potentiometer (2k ohm minimum); local or remote setpoint selected from front panel;
- Digital inputs can be configured to switch between setpoints (either setpoint 1 and 2 or between local setpoint and remote setpoint), between auto and manual control modes, profile hold/run, profile segment release, profile abort, reset latched relays, program selection and more. Functions that can be controlled with the optional digital inputs depend on the options installed.
|
|
Additional InformationClick Here to Download Product Literature
Click Here to Download Detailed Specifications
|
West 1/4 DIN Temperature/Process Control, Universal Input, Self Tuning (Choose options below).
|
West 1/4 DIN Timed Ramp-Dwell Temperature/Process Control, Universal Input, Self Tuning
| |
|
ISE, Inc.
10100 Royalton Rd.
Cleveland, OH 44133
Tel: (440) 237-3200
Fax: (440) 237-1744
Toledo Area Office:
Maumee, OH 43537
Tel: (419) 893-3330
Fax: (419) 893-2151
|
|