Analog Pressure Indicator/Alarm
Analog Pressure Indicator, optional alarm outputs. Includes recorder output.
|
Item Number: GT409
Product Options
* denotes required field
Alarms*
Pressure Range*
|
In Stock For Same Day Shipment We will advise immediately if your
order will be delayed
|
In Stock For Same Day
Shipment
We will advise immediately if your order will be delayed
|
|
-
U NIVERSAL
PRESSURE
INDICATOR
The ISE/Gentan
model GT409 analog indicator/power supply is designed for use with any
four leg, 350 ohm Wheatstone bridge pressure transducer. Zero and span can
be easily adjusted without removing the module. Shunt calibration is a
standard feature.
|
-
EASY TO READ METER
The large 240 degree arc international scale makes the
analog meter easy to read.
|
-
OPTIONAL DUAL ALARM SETPOINTS
Two alarms can be selected for above or below setpoint
control. Relays provide N.O. (normally open) and N.C. (normally closed)
contacts for maximum flexibility. Adjustments are made through pots on the
faceplate.
|
-
VERSATILE
Provides a choice of recorder outputs, damping constant,
transducer sensitivities, input power, shunt-resistor calibrations,
peak-hold, and reset options.
|
Can be set to operate with Gentran or other styles
of transducers.
|
-
EASY INSTALLATION
The easy-to-mount aluminum housing fits a 1/4 DIN cutout.
Slide-type metal brackets hold the case firmly in place and can be
installed quickly. The electronic module can be easily removed for option
selection or service
|
|
|
|
Standard Pressure Ranges: |
|
0-1,500 psig
0-3,000 psig
0-5,000 psig
0-10,000 psig
0-15,000 psig
|
|
|
Accuracy: |
|
|
Display: ±2.0% of full scale
Recorder Output: ±0.1% of full scale
Repeatability: ±0.1% of full scale
Linearity: ±0.1% of full scale
Stability: ±0.1% of full scale
|
|
Physical Characteristics: |
|
|
Size: 1/4 DIN
Meter: Six (6) inch scale 240 degree arc
Operating Temperature: 0-140°F
Weight: 2.5 lbs.
|
|
|
|
Power: |
|
|
106-125 or 200-250 VAC, 50/60 hz, 1/8 Amp maximum
|
|
Calibration: |
|
|
Zero Adjustment: ±35% with front panel pot
Sensitivity Adjustment (Span): 1-2.5 mV/V or 2.5-5.0 mV/V, Switch
selectable and fully adjustable.
Shunt Resistance Calibration: Selectable for Gentran or Dynisco
Response Time (Damping): Selectable at 0.3 or 5.0 seconds
|
|
|
|
Recorder Output: |
|
|
Standard: Selectable 0-1 VDC, 0-2 VDC, 0-5 VDC & 0-10
VDC
Optional: 4-20 mA, Load from 15-600 ohms |
|
|
|
Transducer Power Supply: |
|
|
:8.2 VDC ±5.0% |
|
|
|
Optional Alarm Outputs: |
|
|
Dual Relays: 2 SPDT (Single Pole Double Throw)
Relay Rating: 8 Amp @ 125/250 VAC, 5 Amp @ 30 VDC
Set Point Range: 1-100% of full scale
Accuracy: ±0.3% of full scale
Hysteresis: ±0.5% of full scale
Indication: Front panel LED's
Mode: Above or below set point
Reset: Automatic or manual
|
.