Digital Pressure Indicator/Alarm
|
In Stock For Same Day Shipment We will advise immediately if your
order will be delayed
|
In Stock For Same Day
Shipment
We will advise immediately if your order will be delayed
|
|
-
U NIVERSAL
PRESSURE
INDICATOR
The ISE/Gentan
model GT434 Digital indicator/power supply is designed for use with any
four leg, 350 ohm Wheatstone bridge pressure transducer. Zero and span can
be easily adjusted without removing the module. Shunt calibration is a
standard feature.
|
-
EASY TO READ LED DISPLAY
The large 4½ digit, 1/3 inch LED display is easy to read,
even from a distance. Custom face plates are not required for specific
scales because every unit can be set for 12 different ranges. Other
markings can be easily added for engineering units. The last digit is a
fixed zero.
|
-
OPTIONAL DUAL ALARM SETPOINTS
Two alarms can be selected for above or below setpoint
control. Relays provide N.O. (normally open) and N.C. (normally closed)
contacts for maximum flexibility. Adjustments are made through pots on the
faceplate.
|
-
VERSATILE
Provides a choice of recorder outputs, damping constant,
transducer sensitivities, input power, shunt-resistor calibrations,
peak-hold, and reset options.
|
Can be set to operate with Gentran or other styles
of transducers.
|
-
EASY INSTALLATION
The easy-to-mount aluminum housing fits a 1/4 DIN cutout.
Slide-type metal brackets hold the case firmly in place and can be
installed quickly. The electronic module can be easily removed for option
selection or service
|
|
|
|
Standard Pressure Ranges: |
|
0-1,500 psig
0-3,000 psig
0-5,000 psig
0-10,000 psig
0-15,000 psig
|
|
|
Accuracy: |
|
|
Display: ±0.1% of full scale
Recorder Output: ±0.1% of full scale
Repeatability: ±0.1% of full scale
Linearity: ±0.1% of full scale
Stability: ±0.1% of full scale
|
|
Physical Characteristics: |
|
|
Size: 1/4 DIN
Display: 4½ digit LED, 1/3 inch height, last digit
fixed zero and selectable decimal point
Operating Temperature: 0-140°F
Weight: 2.5 lbs.
|
|
|
|
Power: |
|
|
106-125 or 200-250 VAC, 50/60 hz, 1/8 Amp maximum
|
|
Calibration: |
|
|
Zero Adjustment: ±35% with front panel pot
Sensitivity Adjustment (Span): 1-2.5 mV/V or 2.5-5.0 mV/V, Switch
selectable and fully adjustable.
Shunt Resistance Calibration: Selectable for Gentran or Dynisco
Response Time (Damping): Selectable at 0.3 or 5.0 seconds
|
|
|
|
Recorder Output: |
|
|
Standard: Selectable 0-1 VDC, 0-2 VDC, 0-5 VDC & 0-10
VDC
Optional: 4-20 mA, Load from 15-600 ohms |
|
|
|
Transducer Power Supply: |
|
|
:8.2 VDC ±5.0% |
|
|
|
Optional Alarm Outputs: |
|
|
Dual Relays: 2 SPDT (Single Pole Double Throw)
Relay Rating: 8 Amp @ 125/250 VAC, 5 Amp @ 30 VDC
Set Point Range: 1-100% of full scale
Accuracy: ±0.3% of full scale
Hysteresis: ±0.5% of full scale
Indication: Front panel LED's
Mode: Above or below set point
Reset: Automatic or manual
|
.
|
Price: $475.00
Buy Product Online | Visit Store Home
|
|
|
|
|
|
|
Related Products
Melt Pressure Transducer (Gentran Wiring), 6" Stem - Long Life Extrusion Melt Transducers 6" Stem
Melt Pressure Transducer With Thermocouple (Dynisco Wiring), 6" Stem - Long Life Extrusion Melt Transducers with Integral Type J Thermocouple, 18" Z Option, Dynisco 6 Pin Plug
Melt Pressure Transducer With Thermocouple (Gentran Wiring), 6" Stem - Long Life Extrusion Melt Transducers with Integral Type J Thermocouple
Transducer Cable - Transducer Cable, Pressure Only, No Armor, Gentran Wiring
Transducer Cable (Armored) - Transducer Cable, Pressure Only, Armored, Gentran Wiring
Transducer Cable (Armored) Type J T/C - Transducer Cable, Pressure with J Thermocouple, Armored, Gentran Wiring
|
|
Other Items from Melt Pressure
Melt Pressure Transducer (Gentran Wiring), 6" Stem - Long Life Extrusion Melt Transducers 6" Stem
Transducer Cable - Transducer Cable, Pressure Only, No Armor, Gentran Wiring
Transducer Cable (Armored) - Transducer Cable, Pressure Only, Armored, Gentran Wiring
Transducer Cable (Armored) Type J T/C - Transducer Cable, Pressure with J Thermocouple, Armored, Gentran Wiring
Melt Pressure Transducer With Thermocouple (Gentran Wiring), 6" Stem - Long Life Extrusion Melt Transducers with Integral Type J Thermocouple
Melt Pressure Transducer With Thermocouple (Dynisco Wiring), 6" Stem - Long Life Extrusion Melt Transducers with Integral Type J Thermocouple, 18" Z Option, Dynisco 6 Pin Plug
Analog Pressure Indicator/Alarm - Analog Pressure Indicator, optional alarm outputs. Includes recorder output.
Digital Pressure Indicator/Alarm - Digital Pressure Indicator, optional alarm outputs. Includes recorder output.
Digital Pressure & Temperature Indicator/Alarm - Digital Pressure/Temperature Indicator, optional alarm outputs. Includes recorder output.
|
|
Return To ISE, Inc. Web Store; The Preferred Source for Process Controls, Variacs, Heating Elements and Thermocouples
|
|
|
 |
| Ecommerce powered by MonsterCommerce shopping cart. |
|