The ISE Most Configurations Are In Stock For Same Day Shipment
We will advise immediately if your order will be delayed
The ISE/West 4400 is a powerful Programmer, packed with innovative features to control complex processes. Metal treatment and environmental chambers are typical applications. The 4400 is suitable for controlling multiple slave controllers via comms, for multi-zone processes. It's unique modular construction allows the addition of low cost options at any time. It's simplistic operator interface is preferred by most operators.
We fully configure the control prior to shipment so that it is truly plug & play. Configurations can be easily modified if your requirements change.
- Free-form programming
- Program End/Run relay
- Delayed start
- Power fail recovery
- Auto Hold
- Self-tuning algorithms
- Modbus & ASCII comms
- PC support software


Features
Control Types - Full PID with Pre-tune, Self-tune, Manual Tuning, or On-Off control. Heat only or heat & cool.
Auto/Manual - Selectable from front panel, with bumpless transfer.
Output Configuration - Up to 3 total. Max 2 for control (Heat & Cool), max 2 for Alarms, max 1 for retransmit Process Value or Setpoint.
Alarm 1 & 2 Types - Process high, process low, SP deviation, band, logical OR and hysteresis. Also 1 loop alarm.
Human Interface - 6 buttons, 13mm & 10mm high LED's, 8 digit message display, plus status LED indicators.
PC Configuration - Off-line configuration, profile editing & tracker, via config socket (comms option not required).
Programs Profiles
Number of programs - 8, each with 16 free-form segments (Ramp/Dwell/Join/Repeat/End). Max seg. length 99 hrs 59 mins.
Auto Hold - Fully programmable. Holds program if PV is outside of specified hold band.
EOP Relay - Fitted as standard. Indicates program running or program ended.
Delayed start - Max 99 hours 59mins delay from initiation to program start.
Real Time Clock Option - Allows programmed start on specific days, and intelligent power fail recovery.
Input Input
Thermocouple - J, K, R, S, T, B, L, & N.
RTD - 3 Wire PT100, 50ohm per lead maximum (balanced).
DC Linear - 0-20/4-20mA, 0-50/10-50mV, 0-5/1-5/0-10/2-10V. Scaleable -1999 to 9999, decimal point selectable.
Impedance - >100Mohm for Thermocouple and mV ranges, 47Kohm for V ranges and 4.7ohm for mA ranges.
Accuracy - +/- 0.25% of input span +/- 1 LSD (T/C CJC better than 0.7°C).
Sampling - 4 per second, 14 bit resolution approximately.
Sensor Break Detection - <2 secs (except zero based DC ranges), control O/P's turn off, high alarms activate for T/C and mV ranges, low alarms activate for RTD, mA or V ranges.
Outputs Outputs & Options
Control & Alarm Relays - Contacts SPDT 2Amp resistive at 240V AC, >500,000 operations.
Control SSR Outputs - Drive capability >4.2V DC in 1Kohm (10V 500ohm version available).
Solid State (Triac) Outputs - 0.01 to 1 Amp AC 20 to 280V, 47 to 63Hz.
Control DC Outputs - 0-20/4-20mA into 500ohm max, 0-10/0-5V into 500ohm min. Accuracy typically +/- 0.5%.
Retransmit Outputs - 0-20/4-20mA into 500ohm max, 0-10/0-5V into 500ohm min. Accuracy typically +/- 0.25%.
Event Output Option - 4 program segment event relays, contacts SPST 5Amp resistive at 240V AC, >100,000 operations.
Remote Program Control - Volt-free/TTL inputs for Run/Hold, Abort, X60 (mins/secs) and program selection.
Communications - 2 Wire RS485, 1200 to 9600 Baud, West ASCII and Modbus (selectable).
General Operating & Environmental
Temperature & RH - 0 to 55°C (-20 to 80°C storage), 20% to 95%RH non-condensing.
Power Supply - 100-240Vac 50/60Hz (standard) 7.5VA ; 20-50Vac 50/60Hz (option) 7.5VA & 22-65Vdc (option) 4W.
Front Panel Protection - IEC IP66 (Behind panel protection is IP20).
Approvals and Certification - CE, UL & ULc.