Search
Browse Categories

Partlow MRC 5000 Recorder

Partlow MRC 5000 Recorder / 10 in Circular Chart Recorder / 1 or 2 Universal Inputs / Recorder or Recorder Controller Versions

<< Previous in Recorders Next in Recorders >>
Partlow MRC5000 Circular Chart Recorder
Price:
(Including Options)
Item Number: MRC5000
51000011

Product Options

* denotes required field

First Pen*
Second Pen*
Pen 1 Outputs*
Pen 2 Outputs*
Communications*
Case and Door Options*
Power Supply Options*
Alarms & Communications

Shipment within 1-2 Weeks
*Other models or features may be available. Phone or e-mail for pricing.

 

Partlow MRC 5000 Overview / Design Principle:

Designed with the latest innovations in recording technology, enclosures and functionality, the MRC 5000 is slim, trim and simple. The MRC 5000 is a digital circle chart recorder capable of measuring, recording and controlling up to two process variables from a variety of inputs. Finding a place to install this recorder is easy, with its compact panel depth and short protrusion from the front panel. Hardware options are matrix selectable and are shipped with default settings. The MRC 5000 directly connects to either thermocouple, RTD, mVDC, VDC, or mADC inputs. Changes in input type are easily accomplished in the field through programming. This instrument has a universal power supply, 90-264VAC line voltage at 50-60Hz.

Features and Benefits:

  • Easy and simple in every aspect of operation: programming, testing and calibration
  • Standard easy read display saves setup time, ensures proper configuration and allows for field calibration
  • Slim/trim design reduces your panel depth and saves you money
  • Wide range of power operation
  • More standard input selections, time rotations and optional features
  • Value priced basic recording
Standard Features
Functionality: Record only or high/low limit and record/control.
Display: 4 digit; 0.56" high, red, seven segment LED, 3 button keypad.
Modes: Program, Calibrate, Test and Run; Normal/Display or blank.
Status Indicators: Four red LED alarm status indicators; one green LED pen 2 indicator.
Chart: 10" circular chart; 100 charts furnished with each instrument. Unless otherwise specified, charts shipped with instrument are 0-100 range. 24 hour rotation default setting.
Chart Drive: DC Stepper Motor.
Chart Rotation: User-configurable: 8 hrs, 12 hrs, 24 hrs, 48 hrs or 7 days.
Chart Range: Bottom and top of span -9999 to 9999 units.
Pen Type: One or two disposable fiber tip pen.
Pen Color: Pen 1 (red); Pen 2 (green).
Memory Backup: Non-volatile EEPROM for configuration parameters, calibration and alarm setpoint data.
Construction/Enclosure: Injection molded Noryl case; acrylic window cover.

Operating Characteristics
Operating Temp: 32° to 122°F (0° to 50°C).
Storage Temp: -40° to 149°F (-40° to 65°C).
Humidity: 0% to 90% non-condensing R.H.
Vibration: 0.3 to 100Hz @ 0.2g.

Electrical
Power Consumption: 18VA max.
Line Voltage: 90-264VAC, 47-63Hz.

Outputs
Control Outputs: Relay option; SPDT, contacts rated 5A resistive at 115VAC, 2.5A resistive at 230VAC, 1/8HP at 230VAC (single phase), 250VA at 115/230V.
Alarm Outputs: Process high or low; up to two process alarms for each of two inputs.

Inputs
Thermocouple: J, K, T, R, S.
RTD: 100 ohm, platinum; 0.00385 ohms/ohm/°C.
Volts: 0-10 VDC.
DC Millivolts: 0-25mV, 0 to 50mV; 1050mV, 05V and 15V.
DC Milliamps: 0-20mA; 4-20mA; internal 4.7 ohm shunt resistor.resistor.
Impedance: >100M ohms for TC and mV inputs; 100K ohms for 5V inputs; 4.7 ohms for mA inputs.
RTD Excitation Current: 150 microamps, typical.
Input Scan Rate: 1 scan/sec for non-RTD inputs; 1 scan/1.2 sec for RTD inputs.

Performance
Input Measurement Error: Type J, K, T, R, S and RTD +/-0.25% of span +/-1 degree. mA, mV and VDC: +/-0.25% of scaled span plus 1 least significant digit.
Ambient Temperature Error: 0.01% of span per degree C deviation from 25°C.
Cold Junction Compensation Error: +/-0.2°C @25°C.
Cold Junction Compensation Rejection: +/-0.04°/°C deviation from 25°C.
Linearization Error: TCs: +/-0.25°C typical; +/-0.5°C worst case with exceptions.
RTDs: +/-0.1°C typical; +/-0.3°C worst case.
Common Mode Rejection: >120dB @50/60Hz; 260VAC max.
Normal Mode Rejection: 85dB minimum @ 60Hz or greater.
Isolation: Inputs are a common ground signal.
Chart Accuracy: Recording: 0.5% of chart span. Chart Rotation: +/-0.5% of rotation time.

Communcations Interfaces
Communications Port: RS-485 serial, half duplex.
Protocol: MODBUS RTU.
Bit Rate: 9600/sec.
Parity: Odd.
Address: User-configurable, 1247.

Ratings/Agency Approvals
Safety: UL1092, UL916 and QUXY File E67237, CSA Spec 142 File E67237, CE EN61010-1 1993.
Immunity: CE EN50082-2:1992.
Emissions: EN50081-1:1992 and EN50081-2:1994; EN55022 Class B.
Limit Device: FM Approved File J.I.1D8a1.AF (Class 3545).
Other: ISO 9002 registered.

Protection
NEMA 3 standard; NEMA 4X optional; optional door lock.

Physical Dimensions
Width: 14" (356mm).
Depth: 3.8" (97mm); panel depth: 2.5" (64mm); panel protrusion: 1.3" (33mm).
Height: 14" (356mm).
Weight: 15 lbs (6.8kg).
Mounting/Mounting Position: Panel or wall; up to 30° backward or forward tilt from vertical; up to 10° side tilt from vertical.
Retrofit Adaptor Plate: Will fit Partlow MRC7000 and ARC4100 cutouts.

Options/Accessories
  • Optional process or High/Low Limit alarms.
  • Optional configuration port.
  • Optional digital communications.
  • Optional adaptor plate for convenient retrofit into MRC7000 and 4100 cutouts.
  • NEMA 4X protection optional.

Warranty
2 years.
 

Additional Information

Click here to download literature.
Shopping Cart
Your cart is empty.
 
 
 
 
ISE, Inc.
10100 Royalton Rd.
Cleveland, OH 44133
 
Tel:  (440) 237-3200
Fax: (440) 237-1744
 
 
 
Toledo Area Office:
 
Maumee, OH 43537

Tel:  (419) 893-3330
Fax: (419) 893-2151